Fault Isolation of an Electro-mechanical Linear Actuator

##plugins.themes.bootstrap3.article.main##

##plugins.themes.bootstrap3.article.sidebar##

Published Sep 24, 2018
Matt Kemp Eric J. Martin

Abstract

We apply model-based fault-isolation to an electromechanical linear actuator, and demonstrate its use on an unmanned underwater vehicle mass-shifter. Models incorporating the physics of the motor and of the load, and the effect of the servo-controller, are derived for nominal operations, overload faults, and coupling loss faults. A simple parameter identification method based on close-form solutions during startup and at steady-state is used, and is shown to produce good agreement with measurements. Fault-isolation is done by representing the system as a time-dependent mixture of its models, and selecting the model with the smallest error residual. We tested this in three situations – an actual overload fault, an actual coupling fault, and a false-alarm – and found that the correct model was successfully isolated in each case.

How to Cite

Kemp, M., & Martin, E. J. (2018). Fault Isolation of an Electro-mechanical Linear Actuator. Annual Conference of the PHM Society, 10(1). https://doi.org/10.36001/phmconf.2018.v10i1.539
Abstract 468 | PDF Downloads 633

##plugins.themes.bootstrap3.article.details##

Keywords

Autonomous systems, model-based, fault isolation, actuators

Section
Technical Research Papers